The MultiPlus-II as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features.
Specs For The 12/3000/120-50, 24/3000/70-50, and 48/3000/-35-50
PowerControl & PowerAssist- Yes (on L1 Input)
Transfer Switch- 50A
Maximum AC Input Current- 50A
INVERTER
DC Input Voltage Range:
- 12/3000 = 9.5 - 17V
- 24/3000 = 19V - 33V
- 48/3000 = 38V - 66V
Output
- Output Voltage- 120VAC ± 2%
- Frequency- 60 Hz ± 0.1%
Cont. Output Power at 25°C³- 3000VA
Cont. Output Power at 25°C- 2400W
Cont. Output Power at 40°C- 2200W
Cont. Output Power at 65°C- 1700W
Peak Power- 5500W
Maximum Efficiency
- 12/3000 = 93%
- 24/3000 = 94%
- 48/3000 = 95%
Zero Load Power
- 12/3000 = 13W
- 24/3000 = 13W
- 48/3000 = 11W
Zero Load Power In AES Mode
- 12/3000 = 9W
- 24/3000 = 9W
- 48/3000 = 7W
Zero Load Power In Search Mode
- 12/3000 = 3W
- 24/3000 = 3W
- 48/3000 = 2W
CHARGER
AC Input
- Input Voltage Range- 90 - 140VAC
-
Input Frequency- 45 - 65Hz
Charge Voltage 'Absorption'
- 12/3000 = 14.4V
- 24/3000 = 28.8V
- 48/3000 = 57.6V
Charge Voltage 'Float'
- 12/3000 = 13.8V
- 24/3000 = 27.6V
- 48/3000 = 55.2V
Storage Mode
- 12/3000 = 13.2V
- 24/3000 = 26.4V
- 48/3000 = 52.8V
Max Battery Charge Current
- 12/3000 = 120A
- 24/3000 = 70A
- 48/3000 = 35A
Battery Temperature Sensor- YES
GENERAL
Auxiliary Output- 32A
External AC Current Sensor (Optional)- 100A
Programmable Relay- YES
Protection- a - g
VE.Bus Communication Port- For parallel, split phase, and three phase operation, remote monitoring and system integration
General Purpose Com. Port- Yes x2
Remote On - Off- YES
Operating Temperature Range- -40°F - 140°F (Fan assisted cooling)
Humidity (Non-Condensing)- Max 95%
ENCLOSURE
Material & Color- Steel, Blue RAL 5012
Protection Category- IP22
Battery-Connection- M8 Bolts
120V AC-Connection- 13mm (6AWG)
Weight- 42lb
Dimensions (HxWxD)
- 12/3000 = 22.8" x 10.9" x 5.8"
- 24/3000 = 21.1" x 10.9" x 5.8"
- 48/3000 = 22.5" x 10.9" x 5.8"
STANDARDS
Listings (Only applies to the UL listed version)
- 12/3000 = UL458
- 24/3000 = UL458
- 48/3000 = UL1741
Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16
Emission, Immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 6100-3-3, IEC 61000-6-1, IEC 6100-6-2, IEC 61000-6-3
1) Can be adjusted to 50Hz
2) Protection Key
A) Output Short Circuit
B) Overload
C) Battery Voltage to high
D) Battery Voltage to low
E) Temperature to high
F) 120VAC on inverter output
G) Input Voltage ripple to high
3) Non-linear load, crest factor 3:1
4) Up to 75°F ambient
5) Switches off when no external AC sources available
6) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating- 120V / 4A, DC rating 4A up to 35VDC, and 1A up to 60VDC
7) A.o. to communicate with a Lithium-Ion Battery
8) Dimensions of the not UL1741 Certified model- 21.1" x 10.9" x 5.8"
Specs For The 48/5000/70-95
PowerControl & PowerAssist- YES
Transfer Switch- 95A
Maximum AC Input Current- 95A
INVERTER
DC Input Voltage Range- 38 - 66V
Output
- Output Voltage- 120VAC ± 2%
- Frequency- 60Hz ± 0.1%
Cont. Output Power at 25°C³- 5000VA
Cont. Output Power at 25°C- 4000W
Cont. Output Power at 40°C- 3700W
Cont. Output Power at 65°C- 3000W
Peak Power- 9000W
Maximum Efficiency- 96%
Zero Load Power- 15W
Zero Load Power In AES Mode- 10W
Zero Load Power In Search Mode- 3W
CHARGER
AC Input
- Input Voltage Range- 90-140VAC
- Input Frequency- 45-65Hz
Charge Voltage 'Absorption'- 57.6V
Charge Voltage 'Float'- 55.2V
Storage Mode- 52.8V
Max. Battery Charge Current- 70A
Battery Temperature Sensor- YES
GENERAL
Auxiliary Output- 48A
External AC Current Sensor (Optional)- 100A
Programmable Relay- YES
Protection- a - g
VE.Bus Communication Port- For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port- Yes 2x
Remote On-Off- YES
Operating Temperature Range- -40°F - 140°F (Fan assisted cooling)
Humidity (Non-condensing)- Max 95%
ENCLOSURE
Material & Color- Steel, Blue RAL 5012
Protection Category- IP22
Battery-Connection- M8 Bolts
120V AC-Connection- 35mm (2AWG)
Weight- 71lb
Dimensions (HxWxD)- 26.6" x 13.0" x 6.5"
STANDARDS
Listings (Only applies to the UL listed version)- UL1741 Pending
Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16
Emission, Immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 6100-3-3, IEC 61000-6-1, IEC 6100-6-2, IEC 61000-6-3
1) Can be adjusted to 50Hz
2) Protection Key
A) Output Short Circuit
B) Overload
C) Battery Voltage to high
D) Battery Voltage to low
E) Temperature to high
F) 120VAC on inverter output
G) Input Voltage ripple to high
3) Non-linear load, crest factor 3:1
4) Up to 75°F ambient
5) Switches off when no external AC sources available
6) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating- 120V / 4A, DC rating 4A up to 35VDC, and 1A up to 60VDC
7) A.o. to communicate with a Lithium-Ion Battery
8) Dimensions of the not UL1741 Certified model- 21.1" x 10.9" x 5.8"